Unit Hydrograph Table

<< Click to Display Table of Contents >>

Navigation:  Sewsan 6 User Guide > Hydraulic Analysis and Design > Defining, Editing and Managing Hydrograph Data >

Unit Hydrograph Table

Overview

The Unit Hydrograph table (accessible from main menu  via Unit Hydrographs > Edit Unit Hydrograph) allows the user to edit the unit hydrographs loaded into the system. The latter can be accomplished with the Unit Hydrographs > Load Unit Hydrograph main menu item, which will open a Windows file dialog box for browsing to and loading in files of type Sewsan Unit Hydrograph File (*.SAU). Unit hydrographs can also be loaded directly from within the Unit Hydrograph table by applying the File > Open table menu item. Also note that when the external connections are set, the unit hydrograph file will automatically be loaded when opening the project.

For the calculation of the flow contributed by the unit hydrograph refer to the theory on the contributor hydrograph.

Edits made in the Unit Hydrograph table can be saved via the Unit Hydrographs > Save Unit Hydrograph As... main menu item, or alternatively use the File > Save table menu item (directly from within the Unit Hydrograph table). The Unit Hydrograph table menu also has an export option to Excel  (viz. File > Export to Excel).

Columns

The Unit Hydrograph table consists of columns for the various land use types, such as High Residential (HRes), Meduim Residential(MRes), Low Residential (LRes), Business/Commercial (Bus/Comm), Industrial (Ind), No Data (None) and Large Users (Large).

The above columns contain the hourly ordinates of the hydrograph - 24 data points per column for the hours 00:00 - 23:00. These values define the shape of the unit hydrograph. The maximum value of these entries must be 1.0.

The last three entries in each of the above columns contain the following data:

•Leakage (l/min/UE): Expresses the amount of leakage for this type of UH. Leakage is a constant flow of water into the system, that is added to the outflow of the UH. The leakage amount could be incorporated into the UH itself, but it is often excluded because it can be used to differentiate hydrographs that differ only by a constant factor.

•Peak (l/min/UE): The peak value scales the hydrograph by an absolute quantity.

•AADD (%): Expresses the outflow of this unit hydrograph as a percentage of the incoming Average Annual Daily Demand (AADD). Every structure has percentage AADD fields (e.g. Scen1_Percent_AADD), which is multiplied by the relevant UH AADD% to compute the final percentage for the particular structure. Refer to the calculation of the contributor hydrograph for more information.

 