<< Click to Display Table of Contents >> Navigation: Sewsan 6 Tutorial > Sewsan 6 Tutorial: step-by-step > Alternative way of compiling a model from a CAD drawing > Adding diameters to the pipe data using spatial correlation |
The next step is to add all the diameters to the respective pipes in our GIS model. In the GIS Layer Manager, right-click on the newly created GIS layer, labelled SEWER_EXISTING, and select Edit Database. This will open the database associated with the SEWER_EXISTING layer. Click on the top of the field labelled Field1. This will select and highlight the entire column. Right-click on the title, and select Rename / Restructure. This will open the Restructure Field window. Rename the field Name from Field1 to Diameter, and set the data Type to Real Number. The window should now look like the one below. Select OK to accept the changes. Select File > Close to dismiss the database window.

The next step is to fill the new Diameter field with the data as seen in the CAD window, using spatial correlation. Open the Spatial Text Correlation box via GIS > Tools > Spatial Correlation. On the Import From (A) side, toggle the Cad Layers option, and select SEWER_DIAM as the layer to source data from. On the Import Into (B) side, select from the Into GIS Layer drop-down list the GIS layer labelled SEWER_EXISTING. Then, continue and specify the Diameter field from the Into Field drop-down list. In the area labelled Cad Import Options ( B Contains A ), select the fourth option – Text hook point must be inside or no further than. This specifies how far Albion must search to decide which data must be associated with which link. Enter 10, and select OK.