<< Click to Display Table of Contents >> Navigation: Sewsan 6 Tutorial > Sewsan 6 Tutorial: step-by-step > Alternative way of compiling a model from a CAD drawing > Verifying the correctness (and saving) of the spatial correlation data |
After this spatial correlation is complete, right-click again in the GIS Layer Manager on the layer labelled SEWER_EXISTING, and click on Edit Database.
Click on each record in the table to highlight the pipe in the graphical environment (the data table and the graphical environment are synched). Hereby, you can compare/verify the diameter listed in the table with the CAD text. There might be a mismatch or two, as spatial correlation is only as accurate as the underlying information and the correlation parameters.
Proceed to check and fix any data that has been entered incorrectly. When all the records have been checked and fixed correctly, the next step is to save the database as a shapefile. Click on the red star, next to SEWER_EXISTING. Browse to Documents\GLS\Sewsan\, and save the file as SEWER_EXISTING.shp.
Note: The default file type when saving GIS Layers is set as Sqlite (*.sqlite). Simply change the type from the drop-down list to Shapefile (*.shp).
The CAD drawing has now successfully been converted into a temporary GIS database. We will now continue to convert this layer into a useful Sewsan hydraulic model.