Profiles

<< Click to Display Table of Contents >>

Navigation:  Sewsan 6 Tutorial > Sewsan 6 Tutorial: step-by-step >

Profiles

From the main menu, the Profiles functions allow you to draw sections of the longitudinal profile of pipes in the system (also referred to as long sections) - in respect of ground, invert and cover levels.

 

In order to specify which pipes to include in the long section, select Profiles > Define and Show Elevation Profile. At the ensuing prompts, click on the upstream structure (i.e. Manhole H173), and then on the downstream structure (i.e. Conservancy Tank H116). The Quick Profile window will then appear, which displays the long section plot and underlying data (viz. the sequence of pipes starting from Manhole H173, all the way down to the last pipe in the network, i.e. the pipe from Manhole H117 to Conservancy Tank H116).

 

SEW_Tut_LongSectionPlot_New

 

As can be seen from the above long section table, the invert levels are still incomplete. The following process can be followed to correct the invert levels:

 

By clicking on the Calculate Depths and Slopes button, the long section plot and table should be updated as follows:

 

SEW_Tut_LongSectionPlot2_New

 

Notice how the Slope Type changes from ‘E’, ‘S’ and ‘M’ to ‘EI’.

 

There are two methods/functions to fix the illogical inverts (viz. via Interpolate Inverts or via Smooth Slope):

 

(1) Interpolate Inverts: In order to apply this function, you first have to delete the inverts of the selected pipes, as shown below:

 

SEW_Tut_LongSectionPlot3_New

 

Then, click on the Interpolate Inverts button to interpolate between the currently entered inverts, i.e. downstream of Pipe H121 (228.60) to upstream of Pipe H117 (228.30).

 

SEW_Tut_LongSectionPlot4_New

 

(2) Smooth Slope: We will correct the above by clicking on the Smooth Slope button, and then holding down the Shift key, while selecting the following two pipes, as shown below (note, the selection must be done on the long section plot, and not in the table):

 

SEW_Tut_LongSectionPlot5_New

 

The function interpolates (smoothly) between the upstream invert of the first selected pipe, and the downstream invert of the last selected pipe, i.e. upstream of Pipe H121 (229.20) to downstream of Pipe H117 (227.90):

 

SEW_Tut_LongSectionPlot6_New

 

Here, the yellow highlight indicates that the Temp Depth value is less than the Minimum Depth (m) setting of 2.0, but for the purposes of this exercise, it is acceptable. Click on the Apply changes to model button to update the model, and Close the Quick Profile window.

 

The long section can swiftly be redrawn by selecting Profiles > Show Defined Elevation Profile. This will, again, open the above Quick Profile window, displaying the table and long section plot. Note that the sequence of link numbers that defines the long section can also be edited in the above table.

 

Advanced settings of the long section display can be accessed via Edit > Edit chart (from the Quick Profile window menu). The settings allow the full customisation of the graph, such as definition and set-up of data series, colours, line styles, and axes. However, these advanced long section settings fall outside the scope of this tutorial. Finally, the long section can be printed via File > Print (from the Quick Profile window menu).