There are several different types of structures within a sewer system. These can be divided into 3 main groups:
The manhole is the most frequently used structure type in Sewsan and represents a common manhole. A manhole can have any number of input links and only one output link. There are several different types of manholes. In modelling terms they are identical, the distinction is only made for reference purposes:
•Manhole
•Top End
•Rodding Eye
•Tee-piece
•Sump
•Dummy
•End Manhole
•Interceptor Tank
•Sub-Catchment
•Flow Meter
•WWTP
•Conservancy Tank
•Septic Tank
Manhole information can be edited in the edit box or in the structure data table. The user information can be edited in the Manhole Data Table.
Pump Structures are structures that can have any number of inflow pipes, and any number of output Rising Mains. Pumps are connected to pump structures.
Pump structures are created by the system when the user changes the structure type or when the downstream pipe is changed to a rising main. The user will be warned as the user information will be lost.
Pumps can be connected to pump structures in the Edit Box or in the pump table.
Diversion structures are the only objects in Sewsan that support multiple output pipes. The number of output pipes is not limited.
The number of diversion structures allowed in a system is 1500.
The diversion structure divides the incoming flow between its downstream pipes according to a user defined relationship for the particular inflow.
The user can define up to 10 inflow categories. For each of these inflow categories a percentage of the flow must be assigned to each of the downstream pipes with the total for each category being 100%. The relevant inflow category is found according to the inflow to the diversion structure. The inflow is then split between the downstream pipes according to the defined percentages. If there is only one category, the diversion structure will have a fixed output function.
Diversion structures are created by the system when a topology operation causes more than one downstream pipe to be connected to a structure. The user will be warned before the topology operation is completed as the user information will be lost.
The diversion structure information can be edited in the Edit Box or in the Diversion Table.