<< Click to Display Table of Contents >> Navigation: Sewsan 6 Tutorial > Sewsan 6 Tutorial: step-by-step > Capturing, editing and saving the model data > Changing structure types |
Select the manhole captured for BC_PS (start of the multi-segment capturing), and right-click to open the following pop-up menu. In the list of options in the menu, select Manhole: 10, as shown below. Then, select Convert to. Several options will be available, but for this step, we want to change a Manhole to a Pump Structure, thus select Pump Structure. An additional model layer (Se_Pump_Tables) is used to list all the pumps that are ‘housed’ in the pump structure, and contains all the hydraulic information used in an analysis (more detail later in this tutorial):

This will result in Manhole 10 changing to a type Pump Structure, and as such, will be drawn with a special pump structure symbol (as per the default theme). The downstream pipe will also be converted automatically to a Rising main by Sewsan. Perform a similar procedure for End Manhole 9 (H116), but select Conservancy Tank.