Converting the pipe GIS into a model

<< Click to Display Table of Contents >>

Navigation:  Sewsan 6 Tutorial > Sewsan 6 Tutorial: step-by-step > Alternative way of compiling a model from a CAD drawing >

Converting the pipe GIS into a model

For the pipe GIS data to be converted to a model, the model database must still be open, i.e. the Se_Gravity_Tables, Se_Rising_Tables, etc. layers must be displayed in the GIS Layer Manager.

 

Then, select Manage Models > Merge into Model > Import from GIS. The following dialog box will appear:

 

SEW_Tut_ImportGIStoModelBox_New

 

For this example, the GIS import applies only to the Gravity pipe table of the model (i.e. Se_Gravity_Tables). Select from the Populate from table drop-down list the GIS layer labelled SEWER_EXISTING as the data source, and in the From Field / To Field settings, select the import of the diameter information (matching field names will be listed automatically, as will be the case in this example).

 

SEW_Tut_ImportGIStoModelBox2_New

 

When all the required fields (only Diameter for this example) have been mapped, select OK.

 

Since the manholes have been created automatically, they will not have the correct codes. However, since the CAD drawing contains the manhole codes as text items, we can use the Spatial Correlation function to import the data into the Structure_Code field of the model. The process is similar to correlating the diameters (as shown earlier in this step), but this time we import directly into the model. Ensure that you turn on the visibility of the SEWER_CODES layer, before continuing.

 

SEW_Tut_SpatialTextCorrelationBox3_New

 

The basic foundation of the Sewsan model is now in place. We just need to clean-up the data.

 

The first step in cleaning the model is to ensure that all the gravity pipes drain towards the same point. This can easily be done by right-clicking on End Manhole H116, and then from the context menu, selecting Set Group Flow Direction, as shown in the screen-shot below:

 

SEW_Tut_SetGroupFlowMenu_New

 

The following form will appear. This step is required when the model contains diversion structures. Before clicking on Continue, a selection of all the diversion structures that should be retained needs to be made. The tutorial model has one diversion to select, i.e. Diversion H198. Therefore, select Diversion H198, and click on Continue.

 

SEW_Tut_SetGroupFlowPrompt

 

If you click on the CheckSystemGreen Check Hydraulic Model button, then there should be no errors.

 

Finally, we might want to add some cover levels, since this information is available as text items in the CAD drawing. Other information, if available, can also be added in a similar manner.

 

The process we are going to follow is the same as when we added the diameters to the SEWER_EXISTING GIS layer, and the manhole codes to the Sewsan model. In the Spatial Text Correlation dialog box, we are going to select the SEWER_COVER layer as the source of data, and we are going to import it into the Cover_Level field, in the Se_Structures_Tables model layer, followed by selecting OK. This entire step is shown in the screen-shot below:

 

SEW_Tut_SpatialTextCorrelationBox_New

 

Note: When updating the Cover_Level (m) field of a manhole, the upstream and downstream pipe cover levels (viz. From_Cover_Level (m) and To_Cover_Level (m)) will also be updated automatically (the same applies to ground levels).