<< Click to Display Table of Contents >> Navigation: Sewsan 6 User Guide > Program history, background and theory > Planning Option > Planning Option: Gravity Pipes |
Overview
The planning process is an iterative one. Starting with the diameters defined in the system data, the diameters of all inadequate pipes are iteratively increased, according to the diameters defined in the cost function tables, until there are no more bottlenecks in the system.
The solution, resulting in the minimum diameter pipe, is governed by three criteria:
Diameter must be such that peak flow plus the user defined spare capacity can be accommodated
•Minimum velocity (optional for existing pipes)
The diameter must be such that full bore velocity is more than a user-defined minimum velocity for the pipe (typically 0,7 m/s). If the option to use this criterion for existing pipes is off and the velocity is less than the minimum velocity the user will be warned.
Note on planning and minimum velocities
If the inverts of an existing pipe are unknown the slope type of the pipe can be set to the minimum slope type and the pipe's slope is that slope which will provide the user defined minimum velocity. The minimum slope is therefore a function of the pipe's diameter.
For existing pipes it is assumed that the slopes will remain constant as they are defined by the upstream and downstream manholes. Therefore in the planning analysis all existing pipes with minimum slope types are set to the fixed minimum slope type with the slope equal to the minimum slope calculated on the original diameter.
For new pipes the slope changes (decreases) with increased diameter. Therefore the slopes are not fixed and the minimum slope is calculated for each iteration of diameter. The full flow velocity for these pipes will therefore always be equal to the minimum pipe velocity (in the project settings dialog box). Each of these pipes must also comply with the design criteria that the minimum design velocity is equalled or exceeded. Therefore, it stands to reason that the design minimum velocity must be greater or equal to the minimum pipe velocity. The user will be warned if necessary and the planning analysis will not take place.
•Upstream pipe diameters (optional):
Diameters must be equal to or larger than their largest upstream pipe.
Design of Pipes Parallel to Existing Pipes
Parallel pipe diameters are not calculated for the following:
•New pipes (Existing = false)
•If the original pipe is being upgraded due to it not meeting the minimum velocity design criteria. Including a parallel pipe would have no effect on the velocity of the original pipe.
The user must check that the parallel option is a practical solution. The slope of the parallel pipe is assumed to be equal to that of the existing one. If the slope is very flat the parallel pipe will have to have a large diameter to comply with the minimum velocity being met in the parallel pipe. The large diameter for the parallel pipe will have a corresponding large cost associated with it. It is up to the user to check whether the parallel pipe solutions are practical.