Overview
The results of a planning analysis give a first indication of required pump capacities for planning purposes. The analysis does not consider any pump curves or system heads.
Continuous Pumps
Pump structures with insufficient capacity and continuous pumps are resized during the planning analysis. The new capacity is set equal to the inflow to the pump station plus the required user defined relative spare capacity.
Continuous pumps with excess capacity can also be downsized if so flagged by the user. The capacity of such a pump is decreased to:
•The required capacity calculated on the inflow to the pump, or
•In the case of pumps with existing downstream rising mains to the minimum capacity which satisfies the minimum flow velocity of the downstream rising main.
If there are more than one pump connected to a pump structure the new capacity is allotted to the first pump and all subsequent pumps are given zero capacity.
Variable Speed Pumps
In Sewsan variable speed pumps convey all inflow to the pump structure. These pumps are therefore not designed.