The pump duty flow and pump type are set per pump (there can be more than one pump per pump structure) in the non-geometric pump table. In order to quickly select the correct pump(s), right-click on the pump structure (BC_PS), and navigate to Pump Structure: BC_PS > Pumps > Go to Pump, as shown below:

Set the Pump Duty Flow (L/s) to 5.0, and select “C-Continuous” from the Pump Type field drop-down list. The “C” denotes that the pump will deliver a continuous flow when an analysis is performed. The first alternative setting is “V-Variable”, which implies that the incoming flow is transported (pumped) to the discharge manhole, at the same flow rate. The second alternative setting is “A-Abandon”, which implies that the pump is to be abandoned, and is therefore considered as non-operational when an analysis is performed.

Additionally, the user can set the pump to be considered as 'Operational' or 'Standby' in the Pump_Duty_Status , which is useful when multiple pumps are added to a pump structure. Pumps that are set to 'Standby' allow a value of 0.0 as duty flow, without providing a warning. When multiple pumps are added to a pump structure, the duty flow of the structure is calculated as the sum of all the pumps. It is therefore advised to mark the operational pumps as such and set the duty flows of standby pumps to 0.0.