Structure Fields

<< Click to Display Table of Contents >>

Navigation:  Sewsan 6 User Guide > Appendix > APPENDIX A: Field Descriptions >

Structure Fields

Average Upstream Continuous Pumped Volume as a Percentage of the Volume

Abbreviation: Ave C Pump % Vol

Units: Percentage

Status: Result

That portion of the volume entering the manhole which is due to continuous upstream pumping, expressed as a percentage of the total 24 hour volume entering the manhole:

Ave C Pump % Vol = Ave C Pump/Sim Volume

Average Upstream Continuous Pumping

Abbreviation: Ave U/S Cont Pump

Units: Flow

Status: Result

The combined pumping rate of all of the continuous pumps upstream of the structure. The Peak and Average upstream continuous pumping rate will only differ if there is a diversion structure between the structure and the pump.

The distribution of flow into the pipes downstream of a diversion structure is dependent on the inflow to the diversion structure. If there is a diversion structure between the continuous pump and the structure the average upstream pumping rate is the pumping rate multiplied by the percentage of 24 hour volume of flow routed into the relevant branch of the diversion structure.

Cover Level

Units: m

Status: Data

The elevation of the structure's cover. The value should remain blank if no information is available. Entering a 0 value means that the level is at sea level.

Depth

Units: m

Status: Data

The depth of the structure below the ground level or the cover level of the manhole. The depth is used to check the validity of the structure and pipe invert levels. An error is generated if the depth is negative. The user should then check the structure ground and cover levels and the pipe's upstream elevation level. Note that where no data exists the value should be blank as a zero value is considered a valid entry.

The depth is determined in the following manner, depending on what information is available for the structure:

Order

Available Information

Depth Calculation

1

Defined: User Depth

Depth = User Depth

2

Undefined: User Depth

Defined: Cover Level

Defined: Downstream pipe's upstream invert level

Depth = Depth from the cover level to the downstream pipe's upstream invert level

3

Undefined: User Depth

Undefined: Cover Level

Defined: Ground Level

Defined: Downstream pipe's upstream invert level

Depth = Depth from the ground level to the downstream pipe's upstream invert level

4

Undefined: User Depth

Undefined: Cover Level

Undefined: Ground Level

Undefined: Downstream pipe's upstream invert level

Depth not calculated

For a diversion structure the deepest upstream invert of the downstream pipe is used to calculate the depth.

Exists

Units: None

Status: Data

Indicates whether the structure exists (True) or whether it is a new structure (False). This information is used in the planning analysis.

Flow Percent AADD
 

Units: Percentage

Status: Result

The contributed 24 hour flow volume expressed as a percentage of the combined AADD for the system between any upstream continuous pumps and the structure:

Flow Percent AADD = Local US Flow Volume / Local US AADD x 100

Ground Level

Units: m

Status: Data

The ground level of the structure. The value should remain blank if no information is available. Entering a 0 value means that the level is at sea level.

 

Infiltration Percentage Volume
 

Units: Percentage

Status: Result

The 24 hour volume of infiltration into the system expressed as a percentage of the 24 hour flow volume for the system between any upstream continuous pumps and the structure:

Infiltration Percent Volume = Infiltration Volume/Local US Flow Volume x 100

Infiltration Volume
 

Units: Volume / day

Status: Result

24 hour Infiltration volume for the system upstream of the structure excluding the system upstream of ay upstream continuous pumps.

Land parcel information: Scenario x: UH 1-15

Units: Count

Status: Result

The number of land parcels associated with each unit hydrograph (through landuse) which contribute to the inflow to the downstream pipe. Refer to the calculation of the contributor hydrograph.

Local US AADD
 

Units: Volume / Day

Status: Result

The AADD for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.

Local US Flow Volume
 

Units: Volume / day

Status: Result

The flow upstream of the structure excluding the flow upstream of any upstream continuous pumps:

Local US Flow Volume=Simulated inflow - Upstream continuous pump volume

Max US Flow
 

Units: Flow

Status: Result

The maximum upstream inflow to the structure, excluding the flow from the land parcels which contribute to the downstream pipe and the user hydrograph connected to the structure.

Min US Flow
 

Units: Flow

Status: Result

The minimum upstream inflow to the structure, excluding the flow from the land parcels which contribute to the downstream pipe and the user hydrograph connected to the structure.

Max Overflow Rate

Units: L/s

Status: Result

An overflow occurs at a bottleneck in the system, where the pipe cannot transport the flow into it. The overflow is the volume of flow that exceeds the capacity of the pipe.

It is only calculated if the option to analyse overflows is on.

US Cont Pump Flow
 

Units: L/s

Status: Result

The combined pumping rate of all of the continuous pumps upstream of the structure. The Peak and Average upstream continuous pumping rate will only differ if there is a diversion structure between the structure and the pump.

The distribution of flow into the pipes downstream of a diversion structure is dependent on the inflow to the diversion structure. If there is a diversion structure between the continuous pump and the structure the peak upstream pumping rate is the pumping rate multiplied by the percentage of flow routed into the relevant branch of the diversion structure when the flow into the diversion structure is at its maximum.

Scen1..3 AADD

Units: Flow / Day

Status: Data

The AADD of the land parcels for the chosen landuse scenario which contribute to the pipe downstream of the structure. There are 3 landuse scenarios in Sewsan (viz. Scen1, 2 and 3), which the user can describe. These values are used for the calculation of the contributor hydrograph if the AADD inflow calculation method is used.

Scen1..3 Percentage AADD

Units: Percentage

Status: Data

Percentage of the AADD of the land parcels which contributes to the sewer flow. This value is only used if the AADD inflow calculation method is used. Refer to the calculation of the contributor hydrograph. Note the percentage AADD can be assigned for three different land use scenarios, viz. Scen1, 2 and 3.

Simulated US Flow Volume
 

Units: Volume / Day

Status: Result

The inflow to the structure, excluding the flow from the land parcels which contribute to the downstream pipe and the user hydrograph connected to the structure.

Structure Code

Units: None

Status: Data

The code is the alphanumeric reference to the manhole. It is case sensitive.

Structure Type

Units: None

Status: Data

The type of the structure.

Total US Flow Volume
 

Units: Volume / Day

Status: Result

The flow upstream of the structure including the flow upstream of the continuous pumps.

The Total Upstream flow is routed through pumps:

•Overflow is simulated

The lesser of the upstream inflow volume to the pump and the volume pumped is routed downstream

•Overflow is not simulated

The upstream inflow volume to the pump is routed downstream:

Total US AADD
 

Units: Volume / Day

Status: Result

The total AADD for the system upstream of the structure including the AADD upstream of the continuous pumps.

US Additional Length
 

Units: m

Status: Result

The sum of the additional pipe lengths for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.

US Cont Pumps
 

Units: Count

Status: Result

The number of the continuous pumps upstream of the structure.

US Diversions
 

Units: Count

Status: Result

The number of the diversion structures upstream of the structure excluding those in the the system upstream of any upstream continuous pumps.

US Gravity Length
 

Units: m

Status: Result

The sum of the gravity pipe lengths for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.

US Rising Length
 

Units: m

Status: Result

The sum of rising mains lengths for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.

US No UH 1..15
 

Units: Count

Status: Result

The number of land parcels associated with each unit hydrograph (through landuse) upstream of the structure, excluding those upstream of any upstream continuous pumps.

US No User Hydrograph
 

Units: Count

Status: Result

The number of user hydrographs upstream of the structure, excluding those upstream of any upstream continuous pumps.

US Sump Pumps
 

Units: Count

Status: Result

The number of sump pumps upstream of the structure, excluding those upstream of any upstream continuous pumps.

US Variable Pumps
 

Units: Count

Status: Result

The number of variable speed pumps upstream of the structure, excluding those upstream of any upstream continuous pumps.

User Depth

Units: m

Status: Data

User defined depth of the structure. If a user depth is defined the structure elevation and pipe invert levels are not used to calculate the structure depth.

 

X

Units: Coordinates

Status: Data

The X coordinate of the structure.

Y

Units: Coordinates

Status: Data

The Y coordinate of the structure.