Average Upstream Continuous Pumped Volume as a Percentage of the Volume
Abbreviation: Ave C Pump % Vol
Units: Percentage
Status: Result
That portion of the volume entering the manhole which is due to continuous upstream pumping, expressed as a percentage of the total 24 hour volume entering the manhole:
Ave C Pump % Vol = Ave C Pump/Sim Volume
Average Upstream Continuous Pumping
Abbreviation: Ave U/S Cont Pump
Units: Flow
Status: Result
The combined pumping rate of all of the continuous pumps upstream of the structure. The Peak and Average upstream continuous pumping rate will only differ if there is a diversion structure between the structure and the pump.
The distribution of flow into the pipes downstream of a diversion structure is dependent on the inflow to the diversion structure. If there is a diversion structure between the continuous pump and the structure the average upstream pumping rate is the pumping rate multiplied by the percentage of 24 hour volume of flow routed into the relevant branch of the diversion structure.
Units: m
Status: Data
The elevation of the structure's cover. The value should remain blank if no information is available. Entering a 0 value means that the level is at sea level.
Units: m
Status: Data
The depth of the structure below the ground level or the cover level of the manhole. The depth is used to check the validity of the structure and pipe invert levels. An error is generated if the depth is negative. The user should then check the structure ground and cover levels and the pipe's upstream elevation level. Note that where no data exists the value should be blank as a zero value is considered a valid entry.
The depth is determined in the following manner, depending on what information is available for the structure:
Order |
Available Information |
Depth Calculation |
|---|---|---|
1 |
Defined: User Depth |
Depth = User Depth |
2 |
Undefined: User Depth Defined: Cover Level Defined: Downstream pipe's upstream invert level |
Depth = Depth from the cover level to the downstream pipe's upstream invert level |
3 |
Undefined: User Depth Undefined: Cover Level Defined: Ground Level Defined: Downstream pipe's upstream invert level |
Depth = Depth from the ground level to the downstream pipe's upstream invert level |
4 |
Undefined: User Depth Undefined: Cover Level Undefined: Ground Level Undefined: Downstream pipe's upstream invert level |
Depth not calculated |
For a diversion structure the deepest upstream invert of the downstream pipe is used to calculate the depth.
Units: None
Status: Data
Indicates whether the structure exists (True) or whether it is a new structure (False). This information is used in the planning analysis.
Units: Percentage
Status: Result
The contributed 24 hour flow volume expressed as a percentage of the combined AADD for the system between any upstream continuous pumps and the structure:
Flow Percent AADD = Local US Flow Volume / Local US AADD x 100
Units: m
Status: Data
The ground level of the structure. The value should remain blank if no information is available. Entering a 0 value means that the level is at sea level.
Infiltration Percentage Volume
Units: Percentage
Status: Result
The 24 hour volume of infiltration into the system expressed as a percentage of the 24 hour flow volume for the system between any upstream continuous pumps and the structure:
Infiltration Percent Volume = Infiltration Volume/Local US Flow Volume x 100
Units: Volume / day
Status: Result
24 hour Infiltration volume for the system upstream of the structure excluding the system upstream of ay upstream continuous pumps.
Land parcel information: Scenario x: UH 1-15
Status: Result
The number of land parcels associated with each unit hydrograph (through landuse) which contribute to the inflow to the downstream pipe. Refer to the calculation of the contributor hydrograph.
Units: Volume / Day
Status: Result
The AADD for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.
Units: Volume / day
Status: Result
The flow upstream of the structure excluding the flow upstream of any upstream continuous pumps:
Local US Flow Volume=Simulated inflow - Upstream continuous pump volume
Units: Flow
Status: Result
The maximum upstream inflow to the structure, excluding the flow from the land parcels which contribute to the downstream pipe and the user hydrograph connected to the structure.
Units: Flow
Status: Result
The minimum upstream inflow to the structure, excluding the flow from the land parcels which contribute to the downstream pipe and the user hydrograph connected to the structure.
Units: L/s
Status: Result
An overflow occurs at a bottleneck in the system, where the pipe cannot transport the flow into it. The overflow is the volume of flow that exceeds the capacity of the pipe.
It is only calculated if the option to analyse overflows is on.
Units: L/s
Status: Result
The combined pumping rate of all of the continuous pumps upstream of the structure. The Peak and Average upstream continuous pumping rate will only differ if there is a diversion structure between the structure and the pump.
The distribution of flow into the pipes downstream of a diversion structure is dependent on the inflow to the diversion structure. If there is a diversion structure between the continuous pump and the structure the peak upstream pumping rate is the pumping rate multiplied by the percentage of flow routed into the relevant branch of the diversion structure when the flow into the diversion structure is at its maximum.
Units: Flow / Day
Status: Data
The AADD of the land parcels for the chosen landuse scenario which contribute to the pipe downstream of the structure. There are 3 landuse scenarios in Sewsan (viz. Scen1, 2 and 3), which the user can describe. These values are used for the calculation of the contributor hydrograph if the AADD inflow calculation method is used.
Units: Percentage
Status: Data
Percentage of the AADD of the land parcels which contributes to the sewer flow. This value is only used if the AADD inflow calculation method is used. Refer to the calculation of the contributor hydrograph. Note the percentage AADD can be assigned for three different land use scenarios, viz. Scen1, 2 and 3.
Units: Volume / Day
Status: Result
The inflow to the structure, excluding the flow from the land parcels which contribute to the downstream pipe and the user hydrograph connected to the structure.
Units: None
Status: Data
The code is the alphanumeric reference to the manhole. It is case sensitive.
Units: None
Status: Data
The type of the structure.
Units: Volume / Day
Status: Result
The flow upstream of the structure including the flow upstream of the continuous pumps.
The Total Upstream flow is routed through pumps:
•Overflow is simulated
The lesser of the upstream inflow volume to the pump and the volume pumped is routed downstream
•Overflow is not simulated
The upstream inflow volume to the pump is routed downstream:
Units: Volume / Day
Status: Result
The total AADD for the system upstream of the structure including the AADD upstream of the continuous pumps.
Units: m
Status: Result
The sum of the additional pipe lengths for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.
Units: Count
Status: Result
The number of the continuous pumps upstream of the structure.
Units: Count
Status: Result
The number of the diversion structures upstream of the structure excluding those in the the system upstream of any upstream continuous pumps.
Units: m
Status: Result
The sum of the gravity pipe lengths for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.
Units: m
Status: Result
The sum of rising mains lengths for the system upstream of the structure excluding the system upstream of any upstream continuous pumps.
Units: Count
Status: Result
The number of land parcels associated with each unit hydrograph (through landuse) upstream of the structure, excluding those upstream of any upstream continuous pumps.
Units: Count
Status: Result
The number of user hydrographs upstream of the structure, excluding those upstream of any upstream continuous pumps.
Units: Count
Status: Result
The number of sump pumps upstream of the structure, excluding those upstream of any upstream continuous pumps.
Units: Count
Status: Result
The number of variable speed pumps upstream of the structure, excluding those upstream of any upstream continuous pumps.
Units: m
Status: Data
User defined depth of the structure. If a user depth is defined the structure elevation and pipe invert levels are not used to calculate the structure depth.
Units: Coordinates
Status: Data
The X coordinate of the structure.
Units: Coordinates
Status: Data
The Y coordinate of the structure.